QUANTIMETRIX MEDICAL INDUSTRIES -- URINE CONTROL CAT. 12-2133-1-2 -- 6810-00F009130
===================== Product Identification ===================== Product ID:URINE CONTROL CAT. 12-2133-1-2 MSDS Date:05/01/1972 FSC:6810 NIIN:00F009130 === Responsible Party === Company Name:QUANTIMETRIX MEDICAL INDUSTRIES Address:11953 SO. PRAIRIE AVE. City:HAWTHORNE State:CA ZIP:90250 Info Phone Num:(213) 644-4434 Emergency Phone Num:(213) 644-4434 CAGE:6S304 === Contractor Identification === Company Name:QUANTIMETRIX MEDICAL INDUSTRIES Address:11953 S. PRAIRIE AVENUE Box:City:HAWTHORNE State:CA ZIP:90250 Phone:(213) 644-4434 CAGE:6S304 ============= Composition/Information on Ingredients ============= Ingred Name:SODIUM AZIDE (SARA III) CAS:26628-22-8 RTECS #:VY8050000 Fraction by Wt: 0.1% Other REC Limits:0.1 PPM OSHA PEL:S, C 0.1 PPM(HN3) ACGIH TLV:C 0.11 PPM; 9192 EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS ===================== Hazards Identification ===================== Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:INGESTION: TOXIC. Explanation of Carcinogenicity:NONE Effects of Overexposure:INGESTION: TOXIC. ======================= First Aid Measures ======================= First Aid:INGESTION: CONTACT PHYSICIAN. SKIN/EYES: FLUSH/RINSE AREA W/COPIOUS AMOUNTS OF WATER. ===================== Fire Fighting Measures ===================== Unusual Fire/Explosion Hazard:MAY ACCUMULATE & REACT W/LEAD PLUMBING & CAUSE AN EXPLOSION. ================== Accidental Release Measures ================== Spill Release Procedures:FLUSH & RINSE AREA W/COPIOUS AMOUNTS OF WATER. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:NONE REQUIRED Protective Gloves:RECOMMENDED Work Hygienic Practices:AVOID GETTING INTO EYES. Supplemental Safety and Health THIS REAGENT IS MADE BY MIXING URINE CONTROL WITH A 0.1% AZIDE AQUEOUS SOLUTION. ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES Stability Condition to Avoid:WASHING DOWN LEAD PLUMBING ==================== Disposal Considerations ==================== Waste Disposal Methods:AVOID DISPOSAL IN LEAD PLUMBING. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.