QUANTIMETRIX MEDICAL INDUSTRIES -- URINE CONTROL CAT. 12-2133-1-2 -- 6810-00F009130
=====================  Product Identification  =====================

Product ID:URINE CONTROL CAT. 12-2133-1-2
MSDS Date:05/01/1972
FSC:6810
NIIN:00F009130
=== Responsible Party ===
Company Name:QUANTIMETRIX MEDICAL INDUSTRIES
Address:11953 SO. PRAIRIE AVE.
City:HAWTHORNE
State:CA
ZIP:90250
Info Phone Num:(213) 644-4434
Emergency Phone Num:(213) 644-4434
CAGE:6S304
=== Contractor Identification ===
Company Name:QUANTIMETRIX MEDICAL INDUSTRIES
Address:11953 S. PRAIRIE AVENUE
Box:City:HAWTHORNE
State:CA
ZIP:90250
Phone:(213) 644-4434
CAGE:6S304

=============  Composition/Information on Ingredients  =============

Ingred Name:SODIUM AZIDE  (SARA III)
CAS:26628-22-8
RTECS #:VY8050000
Fraction by Wt: 0.1%
Other REC Limits:0.1 PPM
OSHA PEL:S, C 0.1 PPM(HN3)
ACGIH TLV:C 0.11 PPM; 9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:NO	Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INGESTION: TOXIC.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INGESTION: TOXIC.

=======================  First Aid Measures  =======================

First Aid:INGESTION: CONTACT PHYSICIAN. SKIN/EYES: FLUSH/RINSE AREA
    W/COPIOUS AMOUNTS OF WATER.

=====================  Fire Fighting Measures  =====================

Unusual Fire/Explosion Hazard:MAY ACCUMULATE & REACT W/LEAD PLUMBING &
    CAUSE AN EXPLOSION.

==================  Accidental Release Measures  ==================

Spill Release Procedures:FLUSH & RINSE AREA W/COPIOUS AMOUNTS OF WATER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE REQUIRED
Protective Gloves:RECOMMENDED
Work Hygienic Practices:AVOID GETTING INTO EYES.
Supplemental Safety and Health
THIS REAGENT IS MADE BY MIXING URINE CONTROL WITH A 0.1% AZIDE AQUEOUS
    SOLUTION.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:WASHING DOWN LEAD PLUMBING

====================  Disposal Considerations  ====================

Waste Disposal Methods:AVOID DISPOSAL IN LEAD PLUMBING.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.